Cannulated Screws

6.5mm

Indicated for Sub-capital Femoral Neck Fractures, Tibial Plateau Fractures, Proximal Humerus Fractures, Ankle Arthrodesis, Intercondylar Fractures of the Distal Femur, Sacro-iliac Disruptions, Sub-talar Arthrodesis, and Distal Tibial fractures

Features:

 

  • Cancellous screws with 20mm thread length
  • 3.2mm Guide wire to prevent diversion from desired placement path
  • Extensive size range provides multiple applications
  • Self-drilling self-tapping design reduces operative time and eliminates the possibility of drill breakage
  • Sterile packaged implants for assured implant quality, sterility and traceability
  • Titanium Alloy for strength and biocompatibility
  • Head holding screwdriver and reverse cutting flutes for easy removal

    7.3mm

    Indicated for Sub-capital Femoral Neck Fractures, Tibial Plateau Fractures, Proximal Humerus Fractures, Ankle Arthrodesis, Intercondylar Fractures of the Distal Femur, Sacro-iliac Disruptions, Sub-talar Arthrodesis, and Distal Tibial fractures. 

    Features:

    • Deep cancellous threads provides superior back out resistance
    • 3.2mm Guide wire prevents diversion from desired placement path
    • Extensive size range provides multiple applications
    • 16 and 32mm thread lengths provide improved biomechanical fixation options
    • Self-drilling self-tapping design reduces operative time and eliminates the possibility of drill breakage
    • Combined instrument and implant case for easy implant and instrument identification
    • Titanium Alloy for strength and biocompatibility
    • Head holding screwdriver and reverse cutting flutes for easy removal

    K2 4.0mm Navicular

    Indicated for Malleolar, Talus, Calcaneal and Distal Radius Fractures, and Paediatric Fractures of the long bones.

    Features:

    • Cannulated screw with self-tapping cancellous threads
    • Extensive size range for multiple applications
    • Variable thread length provides improved biomechanical fixation in a variety of bone sizes
    • Only a 1.2mm cannulation to prevent implant failure
    • 316LVM Stainless Steel for high strength
    • Simple combined implant and instrument case

    K2 7.0mm

    Indicated for Sub-capital Femoral Neck Fractures, Tibial Plateau Fractures, Proximal Humerus Fractures, Ankle Arthrodesis, Intercondylar Fractures of the Distal Femur, Sacro-iliac Disruptions, Sub-talar Arthrodesis, and Distal Tibial fractures.

    Features:

  • 16mm, 32mm and fully threaded cannulated self-tapping cancellous screws
  • Extensive size range and three diameters of washers for multiple applications
  • Only a 2.2mm cannulation to prevent implant failure
  • 316LVM Stainless Steel for high strength